|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS456.doc version 2.1 06.01.02 _____________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 456 - 1/3 _____________________________________________________________________________________________________ Measurement condition Ambient temperature: 23 C Input power level: 0 dBm Input power level (impulse work): +16 dBm Source impedance: 50 Load impedance: 50 Construction and pin connection see page 2 Characteristics Remark: Reference level for the relative attenuation arel of the TFS 456 is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 456,3 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo. Data _____________________________________________________________________________________________________ Insertion loss max. 3,5 dB ae = ami (Reference level) _____________________________________________________________________________________________________ Nominal frequency fN 456,3 MHz _____________________________________________________________________________________________________ Centre frequency f0 456,3 MHz _____________________________________________________________________________________________________ 3 dB - bandwidth 8,5 MHz BW _____________________________________________________________________________________________________ Ripple in pass band MHz max. 3 dB fN 2 BW _____________________________________________________________________________________________________ Relative attenuation arel typ. value Variation/ Limitation 256.3 MHz ... 418 MHz min. 65 dB 418 MHz ... 431.3 MHz min. 40 dB 481.3 MHz ... 504 MHz min. 40 dB 504 MHz ...656.3 MHz min. 65 dB min. 60 dB fN - 11,25 MHz _____________________________________________________________________________________________________ Temperature coefficient of frequency -32 ppm/K TCf _____________________________________________________________________________________________________ Operating temperature range - 20 C ... + 75 C _____________________________________________________________________________________________________ Generated: Checked / approved: ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS456.doc version 2.1 06.01.02 _____________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 456 - 2/3 _____________________________________________________________________________________________________ Construction, pin connection and 50 matching network (All dimensions in mm) S456 L1 50 ohm 50 ohm ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS456.doc version 2.1 06.01.02 _____________________________________________________________________________________________________ VI TELEFILTER Filter Specification TFS 456 - 3/3 _____________________________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 ______________________________________________________________________________________________________ VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS456 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |